Technical Specifications
| model | Work pressure(MPa) | Design pressure(MPa) | Operating temperature(°C) | Design temperature(℃ | Effective volume of water tank(m3) | Water seal operating pressure(MPa) | Operating mode | ||
| DCM-10 | 0.02 | 0.2 | 104 | 250 | 5 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-20 | 0.02 | 0.2 | 104 | 250 | 10 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-30 | 0.02 | 0.2 | 104 | 250 | 15 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-40 | 0.02 | 0.2 | 104 | 250 | 20 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-50 | 0.02 | 0.2 | 104 | 250 | 25 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-75 | 0.02 | 0.2 | 104 | 300 | 30/35 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-85 | 0.02 | 0.2 | 104 | 300 | 35/40 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-90 | 0.02 | 0.2 | 104 | 300 | 35/40 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-100 | 0.02 | 0.2 | 104 | 300 | 40 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-130 | 0.02 | 0.2 | 104 | 300 | 40/50 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-150 | 0.02 | 0.2 | 104 | 300 | 50/60 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-200 | 0.02 | 0.2 | 104 | 300 | 70 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-230 | 0.02 | 0.2 | 104 | 300 | 70 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-300 | 0.02 | 0.2 | 104 | 300 | 80/100 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-350 | 0.02 | 0.2 | 104 | 300 | 100 | 0.035 | Constant pressure/sliding pressure | ||
| DCM-400 | 0.02 | 0.2 | 104 | 300 | 100 | 0.035 | Constant pressure/sliding pressure | ||