The rational water circulation loop and unique return water ejector device (for hot water boilers) increase the water velocity in the riser pipe and prevent water-cooled wall tube rupture.
The boiler employs in-furnace inertial dust separation, supplemented by a high-efficiency multi-tube dust collector, ensuring that the boiler's dust emission concentration meets the requirements of Class I areas . The reasonable boiler structure can support its own weight without the need for a steel frame.
The furnace arch, which is energy-saving and has strong radiation, can ensure the stable combustion of bituminous or anthracite coal.
By adopting high-standard, high-quality auxiliary equipment, accessories, and automatic control devices, we ensure the safe and stable operation of the boiler while reducing the labor intensity of boiler operators.
With a compact structure, boilers ranging from 1 to 20 t/h (0.7 to 14 WM) can all be arranged in a single layer.
Technical Parameter Table of DZL Series Coal-fired (Biomass-fired) Steam Boilers
Boiler Model
| DZL1-0.7/1.25-M/A ll | DZL2-0.7 /1.25/1.6- M/A ll | DZL4-1.25/1.6-M/A ll | DZL6-1.25/1.6-M/A ll | DZL8-1.25/1.6-M/A ll | DZL10-1.25/1.6-M/A ll | DZL12-1.25/1.6-M/A ll | DZL15-1.25/1.6-M/A ll | DZL20-1.25/1.6-M/A ll |
Rated evaporation capacity (t/h) | 1 | 2 | 4 | 6 | 8 | 10 | 12 | 15 | 20 |
Rated steam pressure (MPa) | 0.7/1.25 | 0.7/1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
Rated steam temperature (°C) | 170/194 | 170/194/203 | 194/203 | 194/203 | 194/203 | 194/203 | 194/203 | 194/203 | 194/203 |
Rated water supply temperature (°C) | 20 | 105 |
Boiler thermal efficiency (%) | 77.36 | 79.07 | 79.13 | 80.2 | 80.5 | 80.7 | 81.1 | 80.58 | 80.77 |
Heated surface area of the body (m²) | 22.99 | 48.7 | 96.34 | 148.15 | 174.4 | 226.2 | 276 | 374.5 | 669 |
Smoke exhaust temperature (°C) | 158 | 156 | 154 | 152 | 150 | 150 | 148 | 145 | 140 |
fuel | fuel | Class II bituminous coal(biomass) |
Consumption (kg/h) | 150 | 310 | 610 | 910 | 1220 | 1490 | 1715 | 2160 | 2700 |
Maximum transport weight (t) | 18 | 22 | 30.1 | 40 | 21/14 | 23/17 | 23/19 | 21/24 | 25/24 |
Maximum transport size (m) | 4.53×1.9×2.89 | 5.77×2.56×3.47 | 6.73×2.7×3.54 | 8.47×2.97×3.54 | 7.3×3×3.5 | 7.6×3.2×3.5 | 7.6×3.2×3.5 | 7.34×3.37×3.32 | 9.45×3.77×7.1 |
Installation dimensions (m) | 5.1×1.9×3.065 | 5.8×2.6×3.5 | 7.3×2.7×3.5 | 8.5×5.4×5 | 8.1×5.9×6 | 8.43×6×6.5 | 8.6×6×6.5 | 10.2×5.4×7.02 | 10.7×5.5×8.55 |
Technical Parameter Table of DZL Series Coal-fired (Biomass-fired) Hot Water Boilers
Boiler Model
| DZL0.7-0.7/95/70 -M/A II | DZL1.4-0.7/95/70 -M/A II | DZL1.4-0.7/95/70 -M/A II | DZL4.2-1.0/115/70 -M/A II | DZL5.6-1.0/115/70 -M/A II | DZL7.0-1.0/115/70 -M/A II | DZL10.5-1.0/115/70-M/A II | DZL14-1.0/115/70-M/A II |
| Rated thermal power (MW) | 0.7 | 1.4 | 2.8 | 4.2 | 5.6 | 7.0 | 10.5 | 14 |
| Rated operating pressure (MPa) | 0.7 | 0.7 | 0.7 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Rated outlet water temperature (°C) | 95 | 95 | 95 | 115 | 115 | 115 | 115 | 115 |
| Rated inlet water temperature (°C) | 70
|
| Boiler thermal efficiency (%) | 77.39 | 77.7 | 79.4 | 79.6 | 80 | 80.4 | 82 | 81.2 |
| Heated surface area of the body(m²) | 25.3
| 48.3
| 92.7
| 136.3
| 160
| 259.2
| 369.04
| 475.33 |
| circulating water volume | 24 | 48 | 96 | 144 | 192 | 240 | 268 | 268 |
Fuel
| fuel | Class II bituminous coal(biomass) |
Consumption (kg/h)
| 150
| 310
| 610
| 910
| 1100
| 1410
| 2300
| 2900 |
| Heating area | 6000 | 12000 | 24000 | 36000 | 48000 | 60000 | 90000 | 120000 |
Maximum transport weight (t)
| 18
| 22
| 30.1
| 38 | 49
| 28/35
| 25/24
| 30/23.6 |
| Maximum transport dimensions (m) | 5.4×2×3 | 5.9×2.5×3.3 | 5.9×2.77×3.5 | 6.8×3.2×3.4 | 7.1×3.2×3.5 | 7.5×3.2×3.5 | 8.13×3.37×3.16 | 9.1×2.4×3.55 |
| Installation dimensions (m) | 6.5×3.2×4.2 | 6.5×2.6×4.5 | 7.5×4.0×5.0 | 8.5×5.4×5 | 8.6×6×6.3 | 9.11×6×6.3 | 10.5×5.2×9.6 | 11.4×5.8×8.6 |
Note: In case of any changes to the marked "Product Performance and Technical Parameters", the technical documents provided at the time of product delivery shall prevail.