WNS Series Condensing Gas (Oil) Steam Boilers

banner
WNS Series Condensing Gas (Oil) Steam Boilers
WNS Series Condensing Gas (Oil) Steam Boilers
Boiler

WNS Series Condensing Gas (Oil) Steam Boilers

PRODUCT DESCRIPTION:

1. Horizontal, fully wet-back structure, compact and aesthetically pleasing overall layout.

2. Externally integrated finned tube economizer and externally independent vertical condenser, compact structure, easy maintenance.

3. Optimized heat transfer surface design effectively controls flue gas resistance.

4. Variable frequency feedwater and control technology ensures high condensation rate of water vapor in the flue gas.

5. Condenser uses special steel resistant to sulfuric acid and low dew point corrosion, significantly extending service life.

6. A programmable logic controller (PLC) combined with a touch screen and buttons enables a dual-channel intelligent control system for both manual and automatic operation.

7. Comprehensive safety interlock protection functions ensure safe and efficient boiler operation.

8. Multiple boilers can be networked, automatically selecting the number of operating boilers and allocating the load to each boiler without setting up a main control console.

PRODUCT DETAILS

Technical Parameter Table of WNS Series Condensing Gas (Oil) Steam Boiler


Boiler Model ItemsWNS1-0.7-QY WNS1-1.0-QYWNS2-1.0-QY WNS2-1.25-QYWNS3-1.0-QY WNS3-1.25-QYWNS4-1.25-QY WNS4-1.6-QYWNS6-1.25-QY WNS6-1.6-QYWNS8-1.25-QY WNS8-1.6-QYWNS10-1.25-QY WNS10-1.6-QYWNS15-1.25-0Y WNS15-1.6-QYWNS20-1.25-QY WNS20-1.26-QY
Rated evaporation capacity (t/h)10 15 20 
Rated operating pressure (MPa)0.7/1.01.0/1.251.0/1.251.25/1.61.25/1.6  1.25/1.61.25/1.61.25/1.61.25/1.6
Rated steam temperature (°C)170/184184/194184/194194/204194/204   194/204194/204194/204194/204
Water supply temperature (°C) 2020 20 20 20 20 20 20 20
Heated area (m²) OntologyCondenser 24.0615.4 58.1529.64 89.9945.60 112.5953.54 181.1778.25 190.77108.50 229.95165.30 346.20216.20 467.60360.30
Thermal efficiency (%)>98>98>98>98>98>98>98>98>98
Applicable fuels include natural gas, biogas, coke oven gas, light oil, methanol, and biodiesel.
Combustion equipment burner
Total motor power (kW)3.6 7.0 10.5 13.0 19.5 29.5 33 60 90.5 
Water pump modelJGGC2-8 ×16JGGC2.4-8 ×18JGGC4-8 ×22JGGC4.8-8 ×22JGGC6-8 ×19JGGC9-15 ×10JGGC12.5-15 ×11JGGC16-15 ×12JGGC25-35 ×5
fuel consumption Natural gas (Nm³/h)Light oil (kg/h) 7266 144113 216196 288266 432399 576532 720660 1080997 14401204
Maximum transport weight (t)4.0 8.5 8.9 11.3 19.5 22.6 25.8 37.4 46 
Maximum transport dimensions L x W x H (m)3.25 × 1.8 × 2.14.4 × 2.1 × 2.464.6 × 2.31 × 2.624.70 × 2.48 × 2.855.93 × 2.6 × 3.025.85 × 2.8 × 3.17.65 × 2.81 × 3.16.95 × 3.1 × 3.68.3 × 3.4 × 4.02


Technical Parameter Table of WNS Series Condensing Gas (Oil) Hot Water Boilers


 Boiler Model ItemsWNS0.7-0.7 /95/70-QYWNS1.4-0.7 /95/70-QYWNS2.8-0.7 /95/70-QYWNS4.2-1.0 /115/70-QYWNS5.6-1.0 /115/70-QYWNS7-1.0 /115/70-QYWNS10.5-1.0 /115/70-QYWNS14-1.0 /115/70-QY
Rated thermal power (MW)0.7 1.4 2.8 4.2 5.6 7.0 10.5 14 
Rated operating pressure (MPa)0.7 0.7 0.7 1.0 1.0 1.0 1.0 1.0 
Rated outlet temperature (°C)95 95 95 115 115 115 115 115 
Rated inlet water temperature (°C)70 70 70 70 70 70 70 70 
Heated area (m²) OntologyCondenser 2614 58.824.7 112.5945.6 180.9178.25 189.87108.5 205.57148.8 346.19192.1 127.68330.3
Thermal efficiency (%)>98>98>98>98>98>98>98>98
Applicable fuels include natural gas, biogas, coke oven gas, light oil, methanol, and biodiesel.
Combustion equipment burner
fuel consumption Natural gas (Nm³/h)Light oil (kg/h) 7266 144133 288266 432397 576530 720656 1080996 14401327
Maximum transport weight (t)4.0 8.3 13.3 19.5 22.6 25.8 33 46 
Maximum transport dimensions L×W×H (m)3.25 × 1.8 × 2.14.4 × 2.1 × 2.464.7 × 2.48 × 2.856.2 × 2.8 × 3.17.04 × 2.87 × 3.17.3 × 2.88 × 3.168×3.37 ×3.577.77 × 3.7 × 3.99



INQUIRE IMMEDIATELY

+86 13954292899

hyxs@qdhuayuanrongqi.cn

+86 13954292899

微信