YLW Series Coal-fired(Biomass-fired) Organic Heat Carrier Boilers

banner
YLW Series Coal-fired and Biomass Organic Heat Carrier Boilers
YLW Series Coal-fired and Biomass Organic Heat Carrier Boilers
Boiler

YLW Series Coal-fired(Biomass-fired) Organic Heat Carrier Boilers

PRODUCT DESCRIPTION:

The YLW series boilers are horizontal chain grate boilers assembled with square coil tubes. The chain grate and boiler body are shipped separately. After installation on site, they only need to be connected to oil and electricity to be put into operation. The boiler uses a chain grate for mechanical feeding, is equipped with forced draft and induced draft fans for mechanical ventilation, and has a slag remover for mechanical ash removal.

PRODUCT DETAILS

During operation, fuel is fed into the grate for combustion. High-temperature flue gas is reflected by the rear arch to the furnace front, where it enters the furnace chamber. After radiant heat exchange through the radiant heating surface, it enters the convective heating surface for convective heat exchange, then flows to the waste heat boiler, followed by the air preheater, and finally the dust collector. After dust removal, the flue gas is drawn by the induced draft fan shaft and discharged into the atmosphere through the chimney. The boiler's heating surface consists of four parts: the furnace radiant heating surface, the convective tube bundle heating surface, the waste heat boiler, and the air preheater (eco-friendly device).



Technical Parameter Table for YLW Series Coal-fired(Biomass-fired) Organic Heat Carrier Boilers

Boiler ModelYLW-1400 M/A IIYLW-1800 M/A IIYLW-2400 M/A IIYLW-2800 M/A IIYLW-3500 M/A IIYLW-4200 M/A IIYLW-4600 M/A IIYLW-6000 M/A IIYLW-7000 MA IIYLW-8200 M/A II
Rated thermal powerMW1.4 1.8 2.4 2.8 3.5 4.2 4.6 6.0 7.0 8.2 
×10⁴ Kcal/h120 160 200 240 300 360 400 500 600 700 
Rated outlet oil temperature (°C)320 320 320 320 320 320 320 320 320 320 
Rated operating pressure (MPa)0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.0 
Thermal efficiency (%)80808080808080808080
System installed capacity (KW)55 63 76 85 105 125 155 170 193 150 
Expansion tank (m3)2.5 2.5 2.5 3.5 3.5 5.0 5.0 8.0 10 15 
Storage tank (m3)10 10 15 15 25 
Maximum dimensions  of the transported goods(mm)Length (L)5000 5600 6500 6500 7500 7400 8000 8320 9000 9760 
Width (W)2250 2250 2500 2550 2550 2870 2820 3330 3330 3270 
High (H)2450 2750 2800 3200 3200 3300 3350 3250 3350 4010 
Maximum transport weight (kg)11000 12700 13500 14500 16500 22500 29000 33500 36000 35000 



 Boiler ModelYLW-9400 M/A IIYLW-10500 M/A IIYLW-12000 M/A IIYLW-14000 M/A IIYLW-16500 M/A IIYLW-18000 M/A IIYLW-21000 M/A IIYLW-23300 M/A IIYLW-26000 M/A IIYLW-29200 M/A II
Rated thermal powerMW9.4 10.5 12 14 16.5 18 21 23.3 26 29.2 
×104 Kcal/h800 900 1000 1200 1400 1600 1800 2000 2200 2500 
Rated outlet oil temperature (°C)320 320 320 320 320 320 320 320 320 320 
Rated operating pressure (MPa)1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 
Thermal efficiency (%)80808080808081818181
System installed capacity (KW)160 160 260 320 380 450 520 600 700 825 
Expansion tank (m3)15 15 20 20 30 30 30 30 30 30 
Storage tank (m3)25 25 30 30 40 40 60 80 80 80 
Maximum dimensions  of the transported goods(mm)Length (L)9760 10500 11200 10500 11500 11500 11500 11500 11500 12000 
Width (W)3500350035604000425045004500300030003250
High (H)4010 4010 4010 3500350035003850395039504200
Maximum transport weight (kg)24800250002750031000330003500038000175001900022000


Note: In case of any changes to the marked "Product Performance and Technical Parameters", the technical documents provided at the time of product delivery shall prevail.